Theromosyphon System
The objective of a thermosyphon system is to provide a flow of cooling media to the mechanical seal at the required pressure.
The media recirculates through the seal by heat convection generated as the pump shaft rotates through the seal. The media in the vessel is forced into the seal through the bottom line as the hot barrier fluid leaves the seal through the top line back the vessel.
The media flows in the circuit and is cooled by contact with the walls of the tank and the cooling if used. The thermosyphon system is therefore passive and stand -alone, avoiding the cost and complexity of conventional liquid pump .
In order to archives this natural cooling effect, the tank containing a suitable sealing liquid must be located approx. 1-2 m above the seal and the tank with pipes in stainless steel.
Depending on the application, local conditions and client preference, a thermosyphon system can be delivered in a number of different versions by combining several options and basic package.
Circulations in accordance with: -
Item | Description |
---|---|
Tank | Volume: 12, liters approx., media Volume 7 liters Max. Operation Pressure: 16 |
Cooling Coils | Fixed cooling coil is standard in every tank |
Manometer | Displays Pressure in the tank |
Thermometer | Displays media temperature in the seal return line |
Ball Valves | On the “in” and “out” Ports these are used to stop flow and isolated the seal during maintenance |
Fittings | G-series Pipe thread hose fittings for “in” and “out” Ports |
Plugs for options ports | All unused ports are Plugged and sealed. |